Imidaclopride 30.5% SC

Imidaclopride 30.5% SC

Imidacloprid 305 SC


Systemic and Contact Insecticide


It is a systemic insecticide containing imidacloprid active ingredient balance auxillaries and inert material It is used for control of termites in buildings and for the control of Jassids Aphids  Thrips in cotton and brown plant hopper and white Backed Plant hopper in rice


Recommendation


It is used for control of termites in building as follows


Preconstruction the chemical emulsion shall be applied uniformly at the prescribed rate in all the stages of treatment Hand operated sprayer or watering can should be used for application of chemical emulsion


Treatment of masonry foundations


Bottom surface and sides of foundation pits upto a height of 30 cm should be treated 5 ltr chemical emulsion per sq mtr Of surface area

Back fill earth in immediate contact with the foundation structure should be treated 75 ltr per sq mtr of the vertical surface of the substructure for each side

Treatment of rcc foundations treatment should start at a depth of 50cm below ground level 75 ltr per sq mtr

Treatment of top surface of plinth filling the top surface of the consolidated earth within plinth walls shall be treated with chemical emulsion at the rate of 5 ltrm2 of the surface before the sand bed or subgrade is laid

Soil treatment along external perimeter of building earth along the external walls of the building should be rodded at intervals of 15 cm and to a depth of 30 cm exposing the foundation wall surface Chemical solution should be poured along the wall 75 ltr per sq mtr of vertical surface

Treatment of soil under apron along external perimeter of building top surface of the earth over which the apron is to be laid shall be treated with chemical solution  5 ltr per sq mtr of the vertical surface

Post construction


Soil treatment along external perimeter of building earth along the external walls of the building should be rodded at intervals of 15 cm and to a depth of 30 cm exposing the foundation wall surface Chemical solution should be poured along the wall 75 ltr Per sq Mtr Of vertical surface

Treatment of soil under apron along external perimeter of building top surface of the earth over which the apron is to be laid shall be treated with chemical solution  5 ltr per sq Mtr Of the vertical surface

Treatment of soil under floor to prevent entry of termites from cracks soil under floor should be treated Drill 12 mm holes at the junction of floor and wall at 30 cm interval to reach the soil below the chemical solution  1 ltr per hole and seal

Treatment of voids in masonry the movement of termites through masonry walls may be restricted by drilling holes in masonry wall at about 45 degree angle preferably from both sides of the plinth wall at 30 cm interval and the chemical in holes till refusal and seal the holes

Treatment of upper floors in case of infestation in upper floors trat ground floor of the existing building as described above

B Agricultural Crops It should be used for control of Jassids Aphids  Thrips in cotton and brown plant hopper and white Backed Plant hopper on rice  212625 gm aiha 6075 ml formulation diluted in 500750 lit water Waiting period for cotton  rice is 26  37 days respectively


Direction of Use


Imidacloprid 305 SC shall be applied at 0075 ai Concentration ie21 ml formulated product diluted in 1 litre of water for the control of termites during pre and post construction of building Treatment should be as per IS 6313 Part2 2001 for preconstructional chemical treatment and IS 6313Part 3 2001 for post construction treatment


Precaution


Poisonous Handle with care Do not touch or inhale the contents While handling the contents use rubber gloves and face mask


Symptoms of Poisoning


apathy myatonia tremor difficult breathing  myospasms


First Aid


If the product gets into the eyes rinse it out immediately with plenty of water in case of poisoning measure blood pressure and pulse rate frequently Since bradycardia and drop in blood pressure may occur artificial breathing and heart action are recommended Eliminate the active ingredient through gastic lavage and saline laxatives


Antidote


There is no known specific antidote Follow attached directions Treat symptomatically


Disposal of Used Container


The packages shall be broken and buried away from habitation

The used packages shall not be left outside to prevent their reuse

Packages or surplus material and washings should be disposed off in safe manner so as to prevent environment or water pollution

Storage Conditions


The packages containing the insecticide shall be stored in separate rooms or premises away from the rooms or premises used for storing other articles particularly articles or shall be kept in separate almirahs under lock and key depend upon the quantity and nature of the insecticides

The rooms or premises meant for storing the insecticides shall be well built well lit dry well ventilated and of sufficient dimension to avoid contamination with water vapour

Chemical Composition


Imidacloprid ai on 100 basis                                                                     3050 MM

Ethoxylated derivative of styrylated phenols                                                               150 MM


Ethoxylated polymethacrylate in propylene glycol and water 450 MM


Trihydroxy propane 1000 MM


Xanthane Gum 1300 MM


Phenyl methoxy methanol 100 MM


Blend of methyl isothiozolone  its chloro derivative 100 MM


Water solution of Polydimethyl siloxane 100 MM


Water demineralised QS MM


Manufactured by


Riddhi spicility Chemicals


Plot no 608 GIDC Panoli


Ankleshwar Dist Bhurach Gujrat



Manufactured Premises



Plot no 608 GIDC Panoli


Ankleshwar Dist Bhurach Gujrat

Our Coporate Office

RIDDHI SPECIALITY CHEMICALS

Corporate Office: Plot No. 608, 1st Phase, GIDC Panoli , Ta. Ankleshwar, District Bharuch,
Panoli - 394116 ,
Gujarat , India .
Contact Person: Mr UMESH D GONDALIYA
Mobile +919909006960, +919909006962
trusted seller